4-Channel Type K Thermocouple Data Logger Model: DTM-319
Key Features
- -200℃ ~ 1370℃ ( -328℉ ~ 2498℉ )
- Memory capacity: 16,000 records for each channel
- Accuracy:
- -200℃ ~ 200℃: ±(0.3% reading + 1℃)
- 200℃ ~ 400℃: ±(0.5% reading + 1℃)
- 400℃ ~ 1370℃: ±(0.3% reading + 1℃)
- High resolution: 0.1℃ / 0.1℉ (0 ~ 199℃)
- 4-channel thermocouples can be used simultaneously and recorded
- 4-digit LCD display for every tested point; ℃/℉ user-selectable
- HOLD, MAX/MIN, Auto power-off, Low battery indication
- Standard tripod mount connector
- RS-232 interface, real-time display software
Specifications
Measurement Range | -200℃ to 1370℃ (-328℉ to 2498℉) |
---|---|
Accuracy |
-200℃ to 200℃: ±(0.2% reading + 1℃)
200℃ to 400℃: ±(0.5% reading + 1℃)
400℃ to 1370℃: ±(0.2% reading + 1℃)
-328℉ to 200℉: ±(0.5% reading + 1℉)
-200℉ to 200℉: ±(0.2% reading + 1℉)
200℉ to 2498℉: ±(0.3% reading + 1℉)
|
Temperature Scale | ℃ or ℉ user-selectable |
Resolution | 0.1℃ / 0.1℉ (200℃~1370℃: 1℃) |
Sensor | Type K Thermocouple probe |
Sampling Rate | 3 seconds per testing cycle (screen); can record 1 sample/second for 4 channels |
Input Protection | 60V DC or 24V rms AC maximum |
Power Requirement | One 9V battery |
Dimensions | 7.2" x 2.5" x 1.2" (184 x 64 x 30 mm) |
Weight | 7.4 oz (210 g) |
Accessories (Std.) |
RS-232 cable and software for Windows, deluxe carrying case, owner’s manual, TPK-01 bead probe x 2 Optional: USB cable & driver A-010 |
Optional Accessory | AC adaptor (DC 9V), Special Type K thermocouples |
Q & A
Temperature data logger specification clarification
16,000 points per channel. Whether 48 hours is possible depends on your logging interval.
Can DTM-319 record 1 sample/second per channel?
Screen updates every 3 seconds; however, it can record 1 time per second for 4 channels. For rising temperature example (1°C/s), the screen may show step-wise values (e.g., 1,1,1,4,4,4), while the logged data captures each second.
DTM-318 vs DTM-319 update frequency
DTM-318 updates ~1.25 times per second per channel. DTM-319 updates once every 3 seconds per channel on screen; logging can be faster as noted above.
Example update pattern (DTM-319 screen):
T1 | T2 | T3 | T4 | |
---|---|---|---|---|
1 deg C | 1 | 1 | 1 | 1 |
2 deg C | 2 | 1 | 1 | 1 |
3 deg C | 2 | 3 | 1 | 1 |
4 deg C | 2 | 3 | 4 | 1 |
5 deg C | 2 | 3 | 4 | 5 |
6 deg C | 6 | 3 | 4 | 5 |
Videos
Video introduction of four-channel thermocouple data logger DTM-319
Video introduction of four-channel thermocouple data logger DTM-319A